					Digital oxygen sensorMemosens COS51E replace COS51D
					Memosens 2.0 amperometric oxygen sensor for the wastewater industry and utilities
				 | 
		
			| 
					Field of application
				
					Memosens COS51E is perfectly suited for all wastewater and utility applications including hazardous areas. The sensor is highly accurate and moisture-resistant ensuring the safety of your processes. COS51E features Memosens 2.0 digital technology. It is able to store more calibration and process data and thus provides the perfect basis for predictive maintenance and IIoT services. Designed to be low-maintenance with a long operating life, the sensor offers outstanding value for money.
				 
				 
					
						Memosens COS51E measures the dissolved oxygen concentration in:
					 
						
							
								Wastewater treatment plants:- O2 control in the aeration basin
 - Process water treatment and monitoring
							
								Utilities of all industries:- O2 control in the biological treatment
 - Process water treatment and monitoring
							
								Water works:- Status monitoring of drinking water (oxygen enrichment, corrosion protection, etc.)
 - Water quality monitoring in rivers, lakes or seas
 
						The sensor is suitable for hazardous area use (ATEX, FM, CSA).
					 | 
		
			| 
					Benefits
				
					
						
							Wide measuring range: The amperometric measuring principle and cathode design make the sensor suitable for all wastewater applications from industrial to municipal plants.
						
						
							High accuracy: Thanks to its amperometric, three-electrode design, the sensor provides long-term stable measurement with low drift.
						
						
							Increased plant availability: Memosens technology and Liquiline transmitters enable plug & play for fast commissioning and sensor exchange.
						
						
							Non-contact, inductive signal transmission ensures maximum process integrity.
						
						
							Memosens 2.0 digital technology makes the sensor ready for predictive maintenance and IIoT services since it offers extended storage of calibration and process data.
						 | 
		
			| 
					
						
							
								 
									Measuring principle
								
								
									Amperometric oxygen measurement
								
						
							
								 
									Application
								
								
									Typical applications are:- Wastewater treatment plants: oxygen control in aeration basin, process water treatment and monitoring
 .
 - Water plants: status monitoring of drinking water, water quality monitoring in rivers, lakes or seas
 .
 - Utilities of all industries: Oxygen control in biological treatment, process water treatment and monitoring.
						
							
								 
									Characteristic
								
								
									Digital amperometric 3-electrode longterm-stable sensor to measure dissolved oxygen
								
						
							
								 
									Measurement range
								
								
									0.01 to 100 mg/l0.00 to 1000 %SAT
 0 to 2000 hPa
						
					
						
					
						
							
								 
									Material
								
								
									Sensor shaft: POMMembrane cap: POM
 Working electrode: Gold
 Counter and reference electrode: silver/silver halide
 Membrane: ETFE (COS51-TN), FEP (COS51-TF)
						
							
								 
									Dimension
								
								
									Diameter: 40mm (1.57 inch)Shaft length: 146 mm (5.74 inch)
						
							
								 
									Process temperature
								
								
									-5 to 60 °C(20 to 140 °F)
						
							
								 
									Process pressure
								
								
									Max. 5 bar abs(Max. 72.5 psi abs)
						
					
						
							
								 
									Ex certification
								
								
									With ATEX, IECEx, CSA C/US, NEPSI, JapanEx and INMETRO approval for use in Zone 0, Zone 1 and Zone 2 hazardous areas. With CSAC/US approval also in Class I Division 1 hazardous areas in the
 Gas Ex area. Additionally suitable for Class I Division 2.
						
							
								 
									Connection
								
								
									Inductive, contactless connection head with Memosens 2.0 technology
								
						
					 | 
		
			| 
					COS51D-AS800 is replaced by COS51E-AA26TN
				 
					
 
					
						
							|  | Basic model |  
							|  | Oxymax W COS51D |  |  |  
							|  | Approval: |  
							| A | non-hazardous area |  |  |  
							|  | Head type: |  
							| S | thread NPT 3/4; G1; memosens connector |  |  |  
							|  | Cable length: |  
							| 8 | standard version, without cable |  |  |  
							|  | Membrane cap: |  
							| 0 | normal, T90, ca. 3 min. |  |  |  
							|  | Accessories: |  
							| 0 | no |  |  |  |