											Field of application
										
											Memosens CPS16E is suitable for simultaneous pH and ORP measurement in applications with long-term stable conditions. Thanks to its pH and ORP elements, the sensor offers a better process overview and enables tighter process control. Memosens CPS16E features Memosens 2.0 digital technology, offering extended data storage for predictive maintenance. The pH/ORP sensor resists moisture and enables lab calibration which makes the operator's daily tasks easier and maximizes process integrity.
										 
										 
											
												
													
														Long-term monitoring or limit control in processes with stable process conditions:- Chemical processes
 - Pulp and paper industry
 - Power stations (e.g. flue gas cleaning)
 - Incinerator plants
 - Mining
 - Wastewater
													
														Water treatment:- Drinking water
 - Cooling water
 - Well water
 
												With ATEX, IECEx, CSA C/US, NEPSI, Japan, INMETRO approvals for use in hazardous areas, zones 0, 1 and 2.
											 
 | 
								
									| 
											Benefits
										
											
												
													Memosens 2.0 offers extended storage of calibration and process data, enabling better trend identification and providing a future-proof basis for predictive maintenance and enhanced IIoT services.
												
												
													The additional platinum electrode enables constant monitoring of reference impedance and is a reliable indicator of the sensor quality.
												
												
													Simultaneous measurement of pH, ORP and rH values (in rH mode) offers a better process overview and allows for a tighter process control.
												
												
													Robust: Large PTFE ring junction and reference with ion trap prevent poisoning of the sensor.
												
												
													Suitable for harsh applications: Process glass for highly alkaline media and pressure-stable up to 17 bar (246 psi).
												
												
													Reduced operating costs: Lab calibration and fast sensor exchange on site minimize process downtime. Sensor regeneration in the laboratory extends the sensor lifetime.
												
												
													Non-contact, digital signal transmission ensures reliable measurements resulting in maximum process safety.
												 
 | 
								
									| 
											
												
											
												
													
														 
															Application
														
														
															Long-term monitoring and limit control in processes with stable process conditions• Chemical processes
 • Pulp and paper industry
 • Waste incinerators and gas scrubbers
 • Mining
 • Wastewater
												
													
														 
															Characteristic
														
														
															Combination of pH and ORP electrode for standard applications in process technology and environmental engineeringPoison-resistant reference with ion trap
												
													
														 
															Measurement range
														
														
															ORP: –1 500 to 1 500 mVApplication A
 • pH: 1 to 12
 Application B
 • pH: 0 to 14
												
													
														 
															Measuring principle
														
														
															Gel compact electrode with PTFE ring-junction and with ion trapPt-disc as additional ORP element
 rH measurement and control of the reference impedance
												
													
														 
															Design
														
														
															All shaft lengths with temperature sensorAdvanced gel technology
												
													
														 
															Material
														
														
															Sensor shaft: Glass to suit processpH membrane glass: Type A, B
 Metal lead: Ag/AgCl
 Open aperture: PFTE junction, sterilizable
 ORP measuring element: Platinum
 O-ring: FKM
 Process coupling: PPS fiber-glass reinforced
 Nameplate: Ceramic metal oxide
												
													
														 
															Dimension
														
														
															Diameter: 12 mm (0.47 inch)Shaft lengths: 120, 225 and 360 mm
 (4.72, 8.86, 14.17 and 16.73 inch)
												
													
														 
															Process temperature
														
														
															Application A: –15 to 80 °C (5 to 176 °F)Application B: 0 to 135 °C (32 to 275 °F)
												
													
														 
															Process pressure
														
														
															0.8 to 17 bar (11.6 to 246,5 psi) absolute
														
												
											
												
													
														 
															Ex certification
														
														
															With ATEX, IECEx, CSA C/US, NEPSI, Japan Ex and INMETRO approvals for use inhazardous areas Zone 0, Zone 1 and Zone 2
												
													
														 
															Connection
														
														
															Inductive, digital connection head with Memosens 2.0 technology
														
												
											 
 | 
								
									| 
											CPS16D-7BT21 is replaced by CPS16E-AA7BTA2
										 
											 
												
													
														|  | Basic model |  
														|  | Memosens CPS16D |  |  |  
														|  | Version: |  
														| 7 | Basic version |  |  |  
														|  | Application Range: |  
														| BT | 0-14pH; 0-135oC; ORP -1500-1500 mV; rH value; 16 bar; with Ion trap |  |  |  
														|  | Shaft Length: |  
														| 2 | 120 mm |  |  |  
														|  | Approval: |  
														| 1 | Non-hazardous area |  |  |  
											
 | 
											CPS16E-AA7BTA2
										 
											
												
													
														
															Approval
														 
															AA
														 
															Non-hazardous area
														
												
													
														
															Electrode Type
														 
															7
														 
															Basic version, zero point pH 7,0,ORP,rH value, temperature sensor NTC 30k
														
												
													
														
															Application Range
														 
															B
														 
															0-14 pH, 0...135oC, 0,8...17 bar (abs)ORP Platinum, -1500...1500 mV
														
												
													
														
															Reference System
														 
															TA
														 
															PTFE ring junction, ion trap,3 M KCl, Ag/AgCl
														
												
											 
											
 | 
								
									| 
											CPS16D-7AT21 is replaced by CPS16E-AA7ATA2
										 
											 
												
													
														|  | Basic model |  
														|  | Memosens CPS16D |  |  |  
														|  | Version: |  
														| 7 | Basic version |  |  |  
														|  | Application Range: |  
														| AT | 1-12pH; -15-80oC; ORP -1500-1500mV; rH value; 6 bar; with Ion trap |  |  |  
														|  | Shaft Length: |  
														| 2 | 120 mm |  |  |  
														|  | Approval: |  
														| 1 | Non-hazardous area |  |  |  
											
 
											
 | 
											CPS16E-AA7ATA2
										 
											
 
											
												
													
														
															Approval
														 
															AA
														 
															Non-hazardous area
														
												
													
														
															Electrode Type
														 
															7
														 
															Basic version, zero point pH 7,0,ORP,rH value, temperature sensor NTC 30k
														
												
													
														
															Application Range
														 
															A
														 
															1-12 pH, -15...80oC, 0,8...17 bar (abs)ORP Platinum, -1500...1500 mV
														
												
													
														
															Reference System
														 
															TA
														 
															PTFE ring junction, ion trap,3 M KCl, Ag/AgCl
														
												
											 
											
 | 
								
									| 
 | 
								
									| 
 |