					MTL4544/S – MTL5544/S REPEATER POWER SUPPLY 2-channel, 4/20mA, HART®, 2- or 3- wire transmitters 
				 | 
| 
					The MTLx544 provides fully-floating dc supplies for energising two
				 
					conventional 2-wire or 3-wire 4/20mA or HART transmitters located in
				 
					a hazardous area, and repeats the current in other circuits to drive two
				 
					safe-area loads. For smart transmitters, the unit allows bi-directional
				 
					transmission of digital communication signals superimposed on the
				 
					4/20mA loop current. Alternatively, the MTLx544S acts as a current
				 
					sink for a safe-area connection rather than driving a current into the
				 
					load. Separately powered current sources, such as 4-wire transmitters,
				 
					can be connected but will not support HART communication.
				 | 
| 
					SPECIFICATION
				 
					See also common specification
				 
					Number of channels
				 
					Two
				 
					Location of transmitter
				 
					Zone 0, IIC, T4–6 hazardous area if suitably certified
				 
					Div. 1, Group A hazardous location
				 
					Safe-area output
				 
					Signal range:
				 
					4 to 20mA
				 
					Under/over-range:
				 
					0 to 24mA
				 
					Safe-area load resistance (MTLx 544)
				 
					@ 24mA:
				 
					0 to 360Ω
				 
					@ 20mA:
				 
					0 to 450Ω
				 
					Safe-area load (MTLx544S)
				 
					Current sink:
				 
					600Ω max.
				 
					Maximum voltage source:
				 
					24V dc
				 
					Safe-area circuit output resistance: > 1MΩ
				 
					Safe-area circuit ripple
				 
					< 50µA peak-to-peak
				 
					Hazardous-area input
				 
					Signal range:
				 
					0 to 24mA (including over-range)
				 
					Transmitter voltage: 16.5V at 20mA
				 
					Transfer accuracy at 20°C
				 
					Better than 15µA
				 
					Temperature drift
				 
					< 0.8µA/°C
				 
					Response time
				 
					Settles to within 10% of final value within 50µs
				 
					Communications supported
				 
					HART (terminals 1 & 2 and 4 & 5 only)
				 | 
|  | 
|  | 
| 
					LED indicator
				 
					Green: power indication
				 
					Maximum current consumption (with 20mA signals)
				 
					96mA at 24V dc
				 
					Power dissipation within unit (with 20mA signals)
				 
					MTLx544
				 
					1.4W @ 24V dc
				 
					MTLx544S
				 
					1.9W @ 24V dc
				 
					Safety description (each channel)
				 
					Terminals 2 to 1 and 3, and 5 to 4 and 6:
				 
					Uo=28V Io=93mA Po=651mW Um = 253V rms or dc
				 
					Terminals 1 to 3 and 4 to 6:
				 
					Simple apparatus ≤1.5V, ≤0.1A and ≤25mW; can be connected
				 
					without further certification into any IS loop with an open-circuit
				 
					voltage <28V
				 | 
|   | 
|   | 
|   | 