| Gas | 
			
				| 
						
							
								| Measuring Principle | Vortex |  
								| Product headline | The flowmeter for accurate steam flow measurement with wet steam detection, available as compact or remote version. Integrated temp. measuring for mass/ energy flow of saturated steam. Suitable for a wide range of applications; optimized for steam applications. 
 |  
								| Sensor features | Highest process safety – dualsens version enables redundant measurement. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Wet steam detection and measurement for DN 25 to 100 (1 to 4"). Inlet run compensation. 
 |  
								| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology™. Display module with data transfer function. Robust two-chamber housing. 
 |  
								| Nominal diameter range | DN 15 to 300 (½ to 12") 
 |  
								| Wetted materials | Measuring tube: 1.4408 (C3FM); CX2MW similar to Alloy C22, 2.4602 DSC sensor: 1.4435 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
 Connection: 1.4404 (F316/F316L); CX2MW similar to Alloy C22, 2.4602; 1.4408 (CF3M)
 
 |  
								| Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature 
 |  
								| Max. measured error | Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 %
 Mass flow (liquid): ±0.85%
 Mass flow (steam, gas): ±1.7 %
 
 |  
								| Measuring range | Liquid: 0.16 to 2412 m³/h (0.09 to 1420 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
 Steam, gas: 2 to 32 166 m³/h (1.18 to 18 932 ft³/min)
 depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
 
 |  
								| Max. process pressure | PN 40, Class 300, 20K 
 |  
								| Medium temperature range | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
 High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
 
 |  
								| Ambient temperature range | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F)
 Remote version (standard): –40 to +85 °C (–40 to +185 °F)
 Remote version (option): –50 to +85 °C (–58 to +185 °F)
 
 |  
								| Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) 
 |  
								| Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) 
 |  
								| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure
 Transmitter remote version: IP66/67, type 4X enclosure
 
 |  
								| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
 Remote display available
 
 |  
								| Outputs | 4-20 mA HART (passive) 4-20 mA (passive)
 Pulse/frequency/switch output (passive)
 
 |  
								| Inputs | 4-20 mA (passive) 
 |  
								| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus 
 |  
								| Power supply | DC 12 to 35 V (4-20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4-20 mA HART, 4-20 mA)
 DC 12 to 35 V (4-20 mA HART, pulse/frequency/switch output, 4-20 mA input)
 DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
 
 |  
								| Hazardous area approvals | ATEX, IECEx, cCSAus 
 |  
								| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, functional safety PED, CRN, AD 2000
 NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614-1, similar to ASME IX (on request)
 
 |  | 
			
				| Liquids | 
			
				| 
						
							
								| Measuring Principle | Vortex |  
								| Product headline | The flowmeter for accurate steam flow measurement with wet steam detection, available as compact or remote version. Integrated temp. measuring for mass/ energy flow of saturated steam. Suitable for a wide range of applications; optimized for steam applications. 
 |  
								| Sensor features | Highest process safety – dualsens version enables redundant measurement. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Wet steam detection and measurement for DN 25 to 100 (1 to 4"). Inlet run compensation. 
 |  
								| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology™. Display module with data transfer function. Robust two-chamber housing. 
 |  
								| Nominal diameter range | DN 15 to 300 (½ to 12") 
 |  
								| Wetted materials | Measuring tube: 1.4408 (C3FM); CX2MW similar to Alloy C22, 2.4602 DSC sensor: 1.4435 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
 Connection: 1.4404 (F316/F316L); CX2MW similar to Alloy C22, 2.4602; 1.4408 (CF3M)
 
 |  
								| Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature 
 |  
								| Max. measured error | Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 %
 Mass flow (liquid): ±0.85%
 Mass flow (steam, gas): ±1.7 %
 
 |  
								| Measuring range | Liquid: 0.16 to 2412 m³/h (0.09 to 1420 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
 Steam, gas: 2 to 32 166 m³/h (1.18 to 18 932 ft³/min)
 depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
 
 |  
								| Max. process pressure | PN 40, Class 300, 20K 
 |  
								| Medium temperature range | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
 High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
 
 |  
								| Ambient temperature range | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F)
 Remote version (standard): –40 to +85 °C (–40 to +185 °F)
 Remote version (option): –50 to +85 °C (–58 to +185 °F)
 
 |  
								| Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) 
 |  
								| Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) 
 |  
								| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure
 Transmitter remote version: IP66/67, type 4X enclosure
 
 |  
								| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
 Remote display available
 
 |  
								| Outputs | 4-20 mA HART (passive) 4-20 mA (passive)
 Pulse/frequency/switch output (passive)
 
 |  
								| Inputs | 4-20 mA (passive) 
 |  
								| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus 
 |  
								| Power supply | DC 12 to 35 V (4-20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4-20 mA HART, 4-20 mA)
 DC 12 to 35 V (4-20 mA HART, pulse/frequency/switch output, 4-20 mA input)
 DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
 
 |  
								| Hazardous area approvals | ATEX, IECEx, cCSAus 
 |  
								| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025),NAMUR, functional safety PED, CRN, AD 2000
 NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614-1, similar to ASME IX (on request)
 
 |  | 
			
				| Steam | 
			
				| 
						
							
								| Measuring Principle | Vortex |  
								| Product headline | The flowmeter for accurate steam flow measurement with wet steam detection, available as compact or remote version. Integrated temp. measuring for mass/ energy flow of saturated steam. Suitable for a wide range of applications; optimized for steam applications. 
 |  
								| Sensor features | Highest process safety – dualsens version enables redundant measurement. High availability – proven robustness, resistance to vibrations, temperature shocks & water hammer. No maintenance – lifetime calibration. Wet steam detection and measurement for DN 25 to 100 (1 to 4"). Inlet run compensation. 
 |  
								| Transmitter features | Convenient device wiring – separate connection compartment. Safe operation – no need to open the device due to display with touch control, background lighting. Integrated verification – Heartbeat Technology™. Display module with data transfer function. Robust two-chamber housing. 
 |  
								| Nominal diameter range | DN 15 to 300 (½ to 12") 
 |  
								| Wetted materials | Measuring tube: 1.4408 (C3FM); CX2MW similar to Alloy C22, 2.4602 DSC sensor: 1.4435 (316/316L); UNS N06022 similar to Alloy C22, 2.4602
 Connection: 1.4404 (F316/F316L); CX2MW similar to Alloy C22, 2.4602; 1.4408 (CF3M)
 
 |  
								| Measured variables | Volume flow, mass flow, corrected volume flow, energy flow, heat flow difference, temperature 
 |  
								| Max. measured error | Volume flow (liquid): ±0.75 % Volume flow (steam, gas): ±1.00 %
 Mass flow (liquid): ±0.85%
 Mass flow (steam,, gas): ±1.7 %
 
 |  
								| Measuring range | Liquid: 0.16 to 2412 m³/h (0.09 to 1420 ft³/min) depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
 Steam, gas: 2 to 32 166 m³/h (1.18 to 18 932 ft³/min)
 depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a)
 
 |  
								| Max. process pressure | PN 40, Class 300, 20K 
 |  
								| Medium temperature range | Standard: –40 to +260 °C (–40 to +500 °F) High/low temperature (option): –200 to +400 °C (–328 to +752 °F)
 High/low temperature (on request): –200 to +450 °C (–328 to +842 °F)
 
 |  
								| Ambient temperature range | Compact version (standard): –40 to +80 °C (–40 to +176 °F) Compact version (option): –50 to +80 °C (–58 to +176 °F)
 Remote version (standard): –40 to +85 °C (–40 to +185 °F)
 Remote version (option): –50 to +85 °C (–58 to +185 °F)
 
 |  
								| Sensor housing material | Sensor connection housing: AlSi10Mg, coated; 1.4408 (CF3M) 
 |  
								| Transmitter housing material | AlSi10Mg, coated; 1.4404 (316L) 
 |  
								| Degree of protection | Compact version: IP66/67, type 4X enclosure Sensor remote version: IP66/67, type 4X enclosure
 Transmitter remote version: IP66/67, type 4X enclosure
 
 |  
								| Display/Operation | 4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
 Remote display available
 
 |  
								| Outputs | 4-20 mA HART (passive) 4-20 mA (passive)
 Pulse/frequency/switch output (passive)
 
 |  
								| Inputs | 4-20 mA (passive) 
 |  
								| Digital communication | HART, PROFIBUS PA, FOUNDATION Fieldbus 
 |  
								| Power supply | DC 12 to 35 V (4-20 mA HART with/without pulse/frequency/switch output) DC 12 to 30 V (4-20 mA HART, 4-20 mA)
 DC 12 to 35 V (4-20 mA HART, pulse/frequency/switch output, 4-20 mA input)
 DC 9 to 32 V (PROFIBUS PA, pulse/frequency/switch output)
 
 |  
								| Hazardous area approvals | ATEX, IECEx, cCSAus 
 |  
								| Other approvals and certificates | 3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL PED, CRN, AD 2000
 NACE MR0175/MR0103, PMI (on request); welding test acc. to ISO 15614-1, similar to ASME IX (on request)
 
 |  |